Thermocouple Interfacing Usng MAX31855 | JAVA & Pi4J| Raspberry Pi
by WearGenius in Circuits > Raspberry Pi
1309 Views, 2 Favorites, 0 Comments
Thermocouple Interfacing Usng MAX31855 | JAVA & Pi4J| Raspberry Pi
Reading thermocouple data on RAspberry Pi using JAVA and Pi4J with the help of MAX31855 14 bit thermocouple to digital converter. The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed 14-bit, SPI-compatible, read-only format. This converter resolves temperatures to 0.25°C, allows readings as high as +1800°C and as low as -270°C, and exhibits thermocouple accuracy of ±2°C for temperatures ranging from -200°C to +700°C for K-type thermocouples.