How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine

by HDD2 in Workshop > Cars

1 Views, 0 Favorites, 0 Comments

How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine

1.jpg

If you want to do initialization the Service Case EGR cooler exchange must be performed after the EGR cooler exchange by SERDIA2010.

Supplies

Handling in service in the case of an exchange of the EGR cooler to the engine of the BR 2.9 and 3.6 T4i DOConly.

Deutz Decom Communicator

How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine (1).jpg

By replacing the EGR cooler through the service, also the moment (hours of operation) of

exchange must be stored in the engine control unit to reinitialize the term-dependent aging function of the EGR cooler.

How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine (2).jpg

Press “Set time cooler exchange” button

How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine (3).jpg

Current operating hours are taken and written as the date of the cooler exchange into the control

unit

How to Use SerDia2010 to Perform EGR Cooler Exchange for Deutz Engine (4).jpg

Operation completed

Consequence when the term-dependent aging function of the EGR cooler is not initialized or

initialized at the wrong time:

EGR cooler is changed without runtime adjustment in the control unit

- EGR correction is not active

- High smoke values

- Particulate emissions are exceeded

- If necessary, lack of power

EGR cooler is not changed and term-dependent aging function is still activated

- EGR correction is active

- High NOx emissions (the limit is exceeded)